Description
Product Detail
Overview
CSC-211 Multifunction Protection IED is versatile IED designed for protection, control and monitoring of feeders. The devices can be used for line protection in networks that are grounded, low-resistance grounded, ungrounded, or of a compensated neutral point structure. It is able to supervise primary apparatus such as circuit breakers and disconnectors.
Technical Information
Functions
Current protection
– Overcurrent protection
– Earth fault protection
– Neutral earth fault protection
– Sensitive earth fault protection
– Negative-sequence overcurrent protection
– Thermal overload protection
– Overload protection
Voltage protection
– Overvoltage protection
– Undervoltage protection
– Displacement voltage protection
– Breaker protection and control function
– Breaker failure protection
– Dead zone protection
– Synchro-check and energizing check
– Auto-recloser
– Three-pole tripping
Capacitor bank protection
– Unbalanced current protection
– Unbalanced voltage protection
– Undercurrent protection
Load shedding function
– UnderFrequency load shedding function
– Undervoltage load shedding function
– Overload load shedding function
Secondary system supervision
– CT secondary circuit supervision
– VT secondary circuit supervision
Other functions
– Fast busbar protection using reverse interlocking
Control functions
– Circuit breaker, disconnector and other switching devices control
Monitoring functions
– Position of circuit breaker, disconnector and other switching device monitoring
– Circuit breaker status supervision
– Auxiliary contacts of circuit breaker supervision
– Self-supervision
– Fault recorder
Front communication port
– Isolated RS232 port
Rear communication port
– 0-1 isolated electrical RS485 communication ports
– 0-2 Ethernet electrical/ optical communication ports
– Time synchronization port
Communication protocols
– IEC 61850 protocol
– IEC 60870-5-103 protocol
More
Features
Extensivemultifunction IED including protection, control and monitoring functions
Three pole tripping required in sub-transmission and distribution network
A complete protection functions library, include:
– Overcurrent protection
– Earth fault protection
– Neutral earth fault protection
– Sensitive earth fault protection
– Negative-sequence overcurrent protection
– Thermal overload protection
– Overload protection
– Overvoltage protection
– Undervoltage protection
– Displacement voltage protection
– Circuit breaker failure protection
– Dead zone protection
– Synchro-check and energizing check
– Auto-reclose function for three-phase reclosing
– Unbalanced current or voltage protection
– Undercurrent protection
– load shedding function
– Voltage transformer secondary circuit supervision
– Current transformer secondary circuit supervision
Fast overcurrent/busbar protection scheme using IEC61850 GOOSE-message
CB status supervision